常见问题 ThinkPad常见报错信息说明 (Error messages)
2009-06-23知识编号:021225
Error messages
| Symptom or error | FRU or action in sequence | |
| Device address conflict. | 1 | Load “Setup Defaults” in IBM BIOS Setup Utility. |
| 2 | Backup battery. | |
| 3 | System board. | |
| Allocation error for device. | 1 | Load “Setup Defaults” in IBM BIOS Setup Utility. |
| 2 | Backup battery. | |
| 3 | System board. | |
| Failing bits: nnnn. | 1 | DIMM. |
| 2 | System board. | |
| Invalid system configuration | 1 | DIMM. |
| data. | 2 | System board. |
| I/O device IRQ conflict. | 1 | Load “Setup Defaults” in IBM BIOS Setup Utility. |
| 2 | Backup battery. | |
| 3 | System board. | |
| Operating system not found. | 1 | Check that the operating system has no failure and is installed correctly. |
| 2 | Enter IBM BIOS Setup Utility and see whether the hard-disk drive and the diskette drive are properly identified. | |
| 3 | Reseat the hard-disk drive. | |
| 4 | Reinstall the operating system. | |
| 5 | Diskette drive. | |
| 6 | Hard-disk drive. | |
| 7 | System board. | |
| Hibernation error. | 1 | Restore the system configuration to what it was before the computer entered hibernation mode. |
| 2 | If memory size has been changed re-create the hibernation file. | |
| Fan error. | Fan. | |
| Thermal sensing error. | System board. | |
| Authentication of system services failed. Press <Esc> to resume. | The IBM Predesktop Area in the HDD is broken. To use the IBM Predesktop Area get a recovery CD and recover the IBM Predesktop area using it. | |