Error messages
Symptom or error | FRU or action in sequence | |
Device address conflict. | 1. 2. 3. | Load “Setup Defaults” in IBM BIOS Setup Utility. Backup battery. System board. |
Allocation error for device. | 1. 2. 3. | Load “Setup Defaults” in IBM BIOS Setup Utility. Backup battery. System board. |
Failing bits: nnnn. | 1. 2. | DIMM. System board. |
Invalid system configuration data. | 1. 2. | DIMM. System board. |
I/O device IRQ conflict. | 1. 2. 3. | Load “Setup Defaults” in IBM BIOS Setup Utility. Backup battery. System board. |
Operating system not found. | 1. 2. 3. 4. 5. 6. 7. | Check that the operating system has no failure and is installed correctly. Enter IBM BIOS Setup Utility and see whether the hard-disk drive and the diskette drive are properly identified. Reset the hard-disk drive. Reinstall the operating system. Diskette drive. Hard-disk drive. System board. |
Hibernation error. | 1. 2. | Restore the system configuration to what it was before the computer entered hibernation mode. If memory size has been changed re-create the hibernation file. |
Fan error. | Fan. | |
Thermal sensing error. | System board. |